{"id":25,"date":"2026-10-17T14:00:00","date_gmt":"2026-10-17T08:30:00","guid":{"rendered":"https:\/\/vatowatt.com\/blog\/?p=25"},"modified":"2026-10-17T13:35:16","modified_gmt":"2026-10-17T08:05:16","slug":"battery-backup-time-formula","status":"publish","type":"post","link":"https:\/\/vatowatt.com\/blog\/battery-backup-time-formula\/","title":{"rendered":"Battery Backup Time Formula: Calculation Table"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">The battery backup time formula helps you estimate how long an inverter or UPS can run your appliances from a battery. Use the battery&#8217;s Ah rating, bank voltage, total load in watts and the 0.8 efficiency factor, then treat the result as a planning estimate rather than a guarantee.<\/p>\n\n\n\n<aside class=\"ap-card\" aria-label=\"Battery Backup Calculator\">\n<span class=\"ap-card__badge\">Free calculator<\/span>\n<div class=\"ap-card__body\"><p class=\"ap-card__name\">Battery Backup Calculator<\/p><p class=\"ap-card__best\">Best for working out how long an inverter or UPS battery will run a load<\/p><ul class=\"ap-card__features\"><li>Enter battery Ah, voltage and load in watts<\/li><li>Efficiency pre-filled at 0.8<\/li><li>Shows runtime in hours and minutes<\/li><li>Works for inverter, UPS and solar batteries<\/li><\/ul><\/div>\n<div class=\"ap-card__side\"><p class=\"ap-card__price\">Free <small>no sign-up<\/small><\/p><a class=\"ap-card__btn\" href=\"https:\/\/vatowatt.com\/battery-backup-calculator\">Open the calculator \u2192<\/a><\/div>\n<\/aside>\n\n\n\n<h2 class=\"wp-block-heading\">The battery backup time formula (and what each part means)<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">For a steady load, the simple formula is:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Backup time (hours) = (Battery capacity (Ah) \u00d7 Battery voltage (V) \u00d7 Efficiency) \u00f7 Load (W)<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For VatoWatt&#8217;s battery backup calculation, use an efficiency factor of <strong>0.8<\/strong>:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Backup time (hours) = (Ah \u00d7 V \u00d7 0.8) \u00f7 W<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Each input has a specific job:<\/p>\n\n\n\n<figure class=\"wp-block-table ap-table\"><table><thead><tr><th>Input<\/th><th>What it means<\/th><th>Where to find it<\/th><\/tr><\/thead><tbody><tr><td>Battery capacity (Ah)<\/td><td>The battery&#8217;s rated charge capacity<\/td><td>Battery label or datasheet<\/td><\/tr><tr><td>Battery voltage (V)<\/td><td>The nominal voltage of the battery bank<\/td><td>Battery or inverter specification<\/td><\/tr><tr><td>Efficiency (0.8)<\/td><td>An allowance for energy lost in conversion<\/td><td>Use 0.8 for this estimate<\/td><\/tr><tr><td>Load (W)<\/td><td>The combined power drawn by your appliances<\/td><td>Appliance labels or a load calculation<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">The first two values give nominal energy in watt-hours:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Battery energy (Wh) = Ah \u00d7 V<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Multiplying by 0.8 estimates the energy available to the connected load. Dividing watt-hours by watts leaves hours, because a 300 W load uses 300 watt-hours every hour it runs.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For example, a 12 V, 150 Ah battery has 1,800 Wh of nominal energy:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><code>150 Ah \u00d7 12 V = 1,800 Wh<\/code><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">After the 0.8 factor:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><code>1,800 Wh \u00d7 0.8 = 1,440 Wh<\/code><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The 1,440 Wh figure is the useful number for estimating runtime with different loads.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Why we multiply by 0.8: inverter and battery losses<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The calculation does not assume that every watt-hour printed on a battery reaches your fan, lights or router. A battery supplies DC power, while a typical home inverter or UPS converts it to AC. Conversion, electronics, cables and the inverter&#8217;s own operation use some energy.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The 0.8 factor means the calculation allows 80% of the nominal <code>Ah \u00d7 V<\/code> energy to reach the load. It is a practical default for a quick estimate, not a universal efficiency rating for every battery or inverter. If the equipment documentation gives a measured system efficiency, you can use that value instead of 0.8.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The <a href=\"https:\/\/vatowatt.com\/battery-backup-calculator\">VatoWatt Battery Backup Calculator<\/a> keeps this factor visible. That makes it easier to see how changing the battery, load or assumption changes the answer.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Do not confuse the efficiency factor with a promise that you can safely use all of a battery&#8217;s rated capacity. Battery chemistry, the manufacturer&#8217;s recommended discharge limit, temperature and battery condition all affect usable energy. For a battery bank or installation change, use the equipment documentation and a qualified electrician.<\/p>\n\n\n\n<aside class=\"ap-note\"><p>Batteries and inverter banks can deliver dangerous current. Switch off the equipment and use a licensed electrician for installation, bank changes, terminals or wiring.<\/p><\/aside>\n\n\n\n<h2 class=\"wp-block-heading\">Worked example 1: 150 Ah, 12 V battery running 300 W<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">This is a useful home-inverter example for a small load of fans, lights, a router or a television.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Given:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n\n<li>Battery capacity: 150 Ah<\/li>\n\n\n<li>Battery voltage: 12 V<\/li>\n\n\n<li>Efficiency: 0.8<\/li>\n\n\n<li>Total load: 300 W<\/li>\n\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Calculate the estimated usable energy first:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><code>150 \u00d7 12 \u00d7 0.8 = 1,440 Wh<\/code><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Now divide by the load:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><code>1,440 Wh \u00f7 300 W = 4.8 hours<\/code><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Convert the decimal part to minutes:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><code>0.8 \u00d7 60 = 48 minutes<\/code><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Estimated backup time: 4 hours 48 minutes.<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This is the theoretical result for the stated inputs. To run the same calculation with your battery&#8217;s Ah rating and your actual appliance total, use the <a href=\"https:\/\/vatowatt.com\/battery-backup-calculator\">Battery Backup Calculator<\/a>.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/vatowatt.com\/blog\/wp-content\/uploads\/2026\/10\/battery-backup-time-formula-1.webp\" alt=\"The calculator result for a 150 Ah, 12 V battery and 300 W load.\"\/><figcaption class=\"wp-element-caption\">The calculator result for a 150 Ah, 12 V battery and 300 W load.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Worked example 2: two 150 Ah batteries on a 24 V inverter<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The important point in a battery-bank calculation is to enter the <strong>bank<\/strong> voltage and the correct Ah capacity. For two matching 12 V, 150 Ah batteries used as a 24 V bank, the bank is treated as <strong>24 V and 150 Ah<\/strong> for this energy calculation.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For the same 300 W load:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><code>24 V \u00d7 150 Ah \u00d7 0.8 = 2,880 Wh<\/code><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><code>2,880 Wh \u00f7 300 W = 9.6 hours<\/code><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><code>0.6 \u00d7 60 = 36 minutes<\/code><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Estimated backup time: 9 hours 36 minutes.<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The result is twice the single-battery example because the nominal stored energy has doubled from 1,800 Wh to 3,600 Wh. The inverter must support the bank voltage, and the batteries must be suitable for the intended setup. Never mix battery voltages or change terminals based only on this maths.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Worked example 3: 100 Ah and 200 Ah batteries at 12 V<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The same formula works for other common home battery capacities. Keeping the load at 300 W makes the difference easy to see.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">100 Ah, 12 V at 300 W<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><code>100 \u00d7 12 \u00d7 0.8 = 960 Wh<\/code><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><code>960 Wh \u00f7 300 W = 3.2 hours<\/code><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><code>0.2 \u00d7 60 = 12 minutes<\/code><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Estimated backup time: 3 hours 12 minutes.<\/strong><\/p>\n\n\n\n<h3 class=\"wp-block-heading\">200 Ah, 12 V at 300 W<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><code>200 \u00d7 12 \u00d7 0.8 = 1,920 Wh<\/code><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><code>1,920 Wh \u00f7 300 W = 6.4 hours<\/code><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><code>0.4 \u00d7 60 = 24 minutes<\/code><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Estimated backup time: 6 hours 24 minutes.<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">At the same voltage and load, doubling Ah doubles the estimated runtime. It does not double the inverter&#8217;s watt capacity: the inverter still needs to support the appliances&#8217; running and starting demand.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Battery backup time calculation table<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The table below uses a 12 V battery bank and the same 0.8 efficiency factor. Results are in hours and are rounded to two decimal places. A value such as 4.80 hours means 4 hours 48 minutes.<\/p>\n\n\n\n<figure class=\"wp-block-table ap-table\"><table><thead><tr><th>Load<\/th><th>100 Ah, 12 V<\/th><th>150 Ah, 12 V<\/th><th>200 Ah, 12 V<\/th><\/tr><\/thead><tbody><tr><td>100 W<\/td><td>9.60 h<\/td><td>14.40 h<\/td><td>19.20 h<\/td><\/tr><tr><td>200 W<\/td><td>4.80 h<\/td><td>7.20 h<\/td><td>9.60 h<\/td><\/tr><tr><td>300 W<\/td><td>3.20 h<\/td><td>4.80 h<\/td><td>6.40 h<\/td><\/tr><tr><td>400 W<\/td><td>2.40 h<\/td><td>3.60 h<\/td><td>4.80 h<\/td><\/tr><tr><td>500 W<\/td><td>1.92 h<\/td><td>2.88 h<\/td><td>3.84 h<\/td><\/tr><tr><td>600 W<\/td><td>1.60 h<\/td><td>2.40 h<\/td><td>3.20 h<\/td><\/tr><tr><td>700 W<\/td><td>1.37 h<\/td><td>2.06 h<\/td><td>2.74 h<\/td><\/tr><tr><td>800 W<\/td><td>1.20 h<\/td><td>1.80 h<\/td><td>2.40 h<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">To use the table correctly, add the <strong>running watts<\/strong> of the appliances you expect to operate at the same time. Three 10 W LED bulbs and two 60 W fans are a 150 W running load, before adding any router, television or other device. If you need help identifying the total, the <a href=\"https:\/\/vatowatt.com\/power-consumption-calculator\">Power Consumption Calculator<\/a> lets you list appliances and their hours of use.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">UPS backup time: the same formula with a smaller battery<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A small computer UPS uses the same energy relationship, even though its battery may be rated in single-digit Ah rather than 100 Ah or 150 Ah.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For a hypothetical 12 V, 9 Ah UPS battery powering a constant 100 W load:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><code>12 \u00d7 9 \u00d7 0.8 = 86.4 Wh<\/code><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><code>86.4 Wh \u00f7 100 W = 0.864 hours<\/code><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Convert hours to minutes:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><code>0.864 \u00d7 60 = 51.84 minutes<\/code><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Estimated backup time: about 52 minutes.<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This is an estimate under the stated assumptions. A UPS may consume some power even when the connected equipment is light, and it may stop at a low-voltage cutoff before the nominal energy is fully delivered. For a desktop, networking rack or office setup, use the actual load in watts rather than the UPS&#8217;s VA number alone.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Why your real backup is shorter than the formula says<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The formula is useful because it exposes the main relationship, but a real battery is not an ideal energy box. Actual runtime can be lower for several reasons:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n\n<li><strong>The battery may not start fully charged.<\/strong> A battery at a partial state of charge has less energy available than its label suggests.<\/li>\n\n\n<li><strong>The 0.8 factor is an assumption.<\/strong> Actual inverter efficiency, standby consumption and cable losses vary with the equipment and operating load.<\/li>\n\n\n<li><strong>Battery age changes the result.<\/strong> A battery&#8217;s present capacity may be lower than its original rated capacity.<\/li>\n\n\n<li><strong>Temperature affects performance.<\/strong> Very hot or cold conditions can change the energy the battery can deliver.<\/li>\n\n\n<li><strong>Heavy loads draw current faster.<\/strong> Lead-acid batteries generally deliver less usable capacity at higher discharge rates than at the rate used for their capacity rating. This is commonly discussed as the Peukert effect; <a href=\"https:\/\/batteryuniversity.com\/article\/bu-503-how-to-calculate-battery-runtime\" target=\"_blank\" rel=\"noopener\">Battery University explains the relationship<\/a>.<\/li>\n\n\n<li><strong>The load may not be constant.<\/strong> A fridge, pump, cooler or fan can cycle, while a motor may need a short starting surge. The running-watt calculation does not prove that an inverter can start every appliance.<\/li>\n\n\n<li><strong>The inverter can reach its low-voltage cutoff early.<\/strong> Voltage sag under a heavy load or a weak battery can make the system stop before the simple energy division predicts.<\/li>\n\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">For a deeper battery-sizing method, a <a href=\"https:\/\/www.victronenergy.com\/Manuals\/phoenix\/phoenix%20uni\/ph06003.pdf\" target=\"_blank\" rel=\"noopener\">Victron inverter manual<\/a> shows how to total appliance watt-hours and account for inverter losses and standby consumption. For home sizing, use the <a href=\"https:\/\/vatowatt.com\/inverter-load-calculator\">Inverter Load Calculator<\/a> to list appliance watts, quantities, run time and surge factors.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">How to calculate battery backup time safely<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Use this short checklist before relying on a result:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n\n<li>Read the battery capacity and nominal voltage from the label or datasheet.<\/li>\n\n\n<li>Add the running watts of the appliances that will be on together.<\/li>\n\n\n<li>Confirm that the inverter&#8217;s voltage and continuous watt rating match the planned setup.<\/li>\n\n\n<li>Calculate <code>Ah \u00d7 V \u00d7 0.8 \u00f7 W<\/code>.<\/li>\n\n\n<li>Treat the answer as an estimate and leave a practical margin for battery age, temperature, changing loads and cutoff behaviour.<\/li>\n\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">Do not use backup hours as a substitute for checking inverter capacity. Runtime tells you how long the stored energy may last; it does not tell you whether a refrigerator compressor, pump or other motor can start safely.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">FAQ<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">What is the battery backup time formula?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Backup time in hours is <code>(battery Ah \u00d7 battery voltage \u00d7 efficiency) \u00f7 load watts<\/code>. With VatoWatt&#8217;s default estimate, use <code>Ah \u00d7 V \u00d7 0.8 \u00f7 W<\/code>.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">How long will a 150 Ah battery last at 300 W?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">A 12 V, 150 Ah battery gives <code>(150 \u00d7 12 \u00d7 0.8) \u00f7 300 = 4.8 hours<\/code>, or about 4 hours 48 minutes. Actual runtime can be lower because the formula uses an efficiency assumption and nominal battery capacity.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">How do I calculate UPS backup time?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Use the same formula with the UPS battery&#8217;s Ah rating, battery voltage, efficiency factor and the connected load in watts. A small UPS can have a much shorter runtime because its battery stores far fewer watt-hours than a home inverter battery.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Does a higher Ah battery always give more backup?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">At the same voltage, a higher Ah rating gives more nominal watt-hours, so the estimated runtime increases for the same load. The inverter still needs enough continuous and surge capacity for the appliances you connect.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Why is my actual backup time lower than the table?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The table assumes a full battery, a constant load and the 0.8 factor. Battery age, temperature, discharge rate, inverter standby draw, voltage cutoff and changing appliance loads can all reduce actual runtime.<\/p>\n\n\n\n<aside class=\"ap-cta\" aria-label=\"Calculate your battery backup\"><div class=\"ap-cta__content\"><p class=\"ap-cta__eyebrow\">Check your numbers<\/p><p class=\"ap-cta__title\">Calculate your battery backup<\/p><p class=\"ap-cta__text\">Enter your battery Ah, voltage and load to get an estimated runtime in hours and minutes.<\/p><\/div><a class=\"ap-cta__btn\" href=\"https:\/\/vatowatt.com\/battery-backup-calculator\">Open calculator<\/a><\/aside>\n\n\n\n<h2 class=\"wp-block-heading\">Related calculators<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n\n<li><a href=\"https:\/\/vatowatt.com\/battery-backup-calculator\">Battery Backup Calculator<\/a> \u2014 estimate runtime from Ah, voltage and load.<\/li>\n\n\n<li><a href=\"https:\/\/vatowatt.com\/inverter-load-calculator\">Inverter Load Calculator<\/a> \u2014 total appliance watts and account for surge.<\/li>\n\n\n<li><a href=\"https:\/\/vatowatt.com\/power-consumption-calculator\">Power Consumption Calculator<\/a> \u2014 estimate appliance energy use and units.<\/li>\n\n\n<li><a href=\"https:\/\/vatowatt.com\/\">VA to Watt Converter<\/a> \u2014 convert an inverter or UPS VA rating to watts.<\/li>\n\n\n<li><a href=\"https:\/\/vatowatt.com\/watt-to-va\">Watt to VA Converter<\/a> \u2014 find the VA rating for a watt load.<\/li>\n\n\n<li><a href=\"https:\/\/vatowatt.com\/solar-panel-calculator\">Solar Panel Calculator<\/a> \u2014 estimate panel count from daily energy use.<\/li>\n\n<\/ul>\n\n\n\n<script type=\"application\/ld+json\">{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the battery backup time formula?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Backup time in hours is (battery Ah \u00d7 battery voltage \u00d7 efficiency) \u00f7 load watts. With VatoWatt's default estimate, use Ah \u00d7 V \u00d7 0.8 \u00f7 W.\"}}, {\"@type\": \"Question\", \"name\": \"How long will a 150 Ah battery last at 300 W?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"A 12 V, 150 Ah battery gives (150 \u00d7 12 \u00d7 0.8) \u00f7 300 = 4.8 hours, or about 4 hours 48 minutes. Actual runtime can be lower because the formula uses an efficiency assumption and nominal battery capacity.\"}}, {\"@type\": \"Question\", \"name\": \"How do I calculate UPS backup time?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Use the same formula with the UPS battery's Ah rating, battery voltage, efficiency factor and the connected load in watts. A small UPS can have a much shorter runtime because its battery stores far fewer watt-hours than a home inverter battery.\"}}, {\"@type\": \"Question\", \"name\": \"Does a higher Ah battery always give more backup?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"At the same voltage, a higher Ah rating gives more nominal watt-hours, so the estimated runtime increases for the same load. The inverter still needs enough continuous and surge capacity for the appliances you connect.\"}}, {\"@type\": \"Question\", \"name\": \"Why is my actual backup time lower than the table?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The table assumes a full battery, a constant load and the 0.8 factor. Battery age, temperature, discharge rate, inverter standby draw, voltage cutoff and changing appliance loads can all reduce actual runtime.\"}}]}<\/script>\n","protected":false},"excerpt":{"rendered":"Use the battery backup time formula with Ah, volts, watts and 0.8 efficiency to calculate UPS runtime, check 12 V examples and use the load table.","protected":false},"author":2,"featured_media":26,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"csco_singular_sidebar":"","csco_page_header_type":"","csco_page_load_nextpost":"","footnotes":""},"categories":[4],"tags":[8,5,6,9,7],"class_list":["post-25","post","type-post","status-publish","format-standard","has-post-thumbnail","category-batteries","tag-batteries","tag-battery-backup","tag-inverter","tag-power-cuts","tag-ups","cs-entry"],"_links":{"self":[{"href":"https:\/\/vatowatt.com\/blog\/wp-json\/wp\/v2\/posts\/25","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/vatowatt.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/vatowatt.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/vatowatt.com\/blog\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/vatowatt.com\/blog\/wp-json\/wp\/v2\/comments?post=25"}],"version-history":[{"count":1,"href":"https:\/\/vatowatt.com\/blog\/wp-json\/wp\/v2\/posts\/25\/revisions"}],"predecessor-version":[{"id":53,"href":"https:\/\/vatowatt.com\/blog\/wp-json\/wp\/v2\/posts\/25\/revisions\/53"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/vatowatt.com\/blog\/wp-json\/wp\/v2\/media\/26"}],"wp:attachment":[{"href":"https:\/\/vatowatt.com\/blog\/wp-json\/wp\/v2\/media?parent=25"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/vatowatt.com\/blog\/wp-json\/wp\/v2\/categories?post=25"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/vatowatt.com\/blog\/wp-json\/wp\/v2\/tags?post=25"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}