{"id":38,"date":"2026-10-18T19:30:00","date_gmt":"2026-10-18T14:00:00","guid":{"rendered":"https:\/\/vatowatt.com\/blog\/?p=38"},"modified":"2026-10-18T19:30:00","modified_gmt":"2026-10-18T14:00:00","slug":"inverter-1-5-ton-ac","status":"publish","type":"post","link":"https:\/\/vatowatt.com\/blog\/inverter-1-5-ton-ac\/","title":{"rendered":"Inverter for AC: 1.5 Ton Size &#038; Battery Guide"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">An inverter for AC must be sized from the air conditioner\u2019s actual power consumption, not just its 1.5-ton cooling label. Read the BEE label, add the other appliances that will run, check compressor startup power and then size the battery for the hours you need.<\/p>\n\n\n\n<aside class=\"ap-card\" aria-label=\"Inverter Load Calculator\">\n<span class=\"ap-card__badge\">Free calculator<\/span>\n<div class=\"ap-card__body\"><p class=\"ap-card__name\">Inverter Load Calculator<\/p><p class=\"ap-card__best\">Best for sizing a home inverter and battery bank from a list of appliances<\/p><ul class=\"ap-card__features\"><li>Add each appliance with watts, quantity and hours<\/li><li>Surge factor options 1x\/2x\/3x\/5x for motors, fridge, AC<\/li><li>12 V, 24 V or 48 V system choice<\/li><li>Suggests battery Ah using 85% inverter efficiency and 50% depth of discharge<\/li><\/ul><\/div>\n<div class=\"ap-card__side\"><p class=\"ap-card__price\">Free <small>no sign-up<\/small><\/p><a class=\"ap-card__btn\" href=\"https:\/\/vatowatt.com\/inverter-load-calculator\">Open the calculator \u2192<\/a><\/div>\n<\/aside>\n\n\n\n<h2 class=\"wp-block-heading\">Short answer: what size inverter does a 1.5-ton AC need?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">There is no single inverter size for every 1.5-ton AC. The BEE label gives you two different numbers: cooling capacity and power consumption. Use the power-consumption number for the running load, then check the inverter\u2019s continuous and peak ratings.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This table shows the maths for simple planning examples. These are not universal AC wattages; replace each example with the power shown on your own AC\u2019s label or technical sheet.<\/p>\n\n\n\n<figure class=\"wp-block-table ap-table\"><table><thead><tr><th>AC size<\/th><th>Example power input<\/th><th>Running VA at PF 0.8<\/th><th>What the number means<\/th><\/tr><\/thead><tbody><tr><td>1 ton<\/td><td>1,000 W<\/td><td>1,250 VA<\/td><td>Add other loads and startup headroom<\/td><\/tr><tr><td>1.5 ton<\/td><td>1,500 W<\/td><td>1,875 VA<\/td><td>AC alone, before surge or other appliances<\/td><\/tr><tr><td>2 ton<\/td><td>2,000 W<\/td><td>2,500 VA<\/td><td>A planning example, not a model specification<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">For the 1.5-ton example, a 2,000 VA inverter is only just above the 1,875 VA AC-only figure; once you add other loads and normal sizing margin, it may be too small. A 2.5 kVA-class inverter may pass the continuous-load check for this example, but its peak rating must also handle the compressor and any appliances starting at the same time.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">What you need before sizing<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Collect these numbers before choosing an inverter:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n\n<li>The AC\u2019s <strong>Power Consumption (W)<\/strong> from its BEE label or manufacturer specification. Do not use <strong>Cooling Capacity (W)<\/strong> as the electrical load.<\/li>\n\n\n<li>The AC type and compressor information. A variable-speed AC can change its input power as the room cools; a fixed-speed compressor has a different starting pattern.<\/li>\n\n\n<li>The wattage of every other appliance you want during an outage: fans, LED bulbs, router, television, refrigerator or pump.<\/li>\n\n\n<li>Your desired backup time, such as 1 hour, 4 hours or 8 hours.<\/li>\n\n\n<li>The battery system voltage you are considering: 12 V, 24 V or 48 V.<\/li>\n\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">The official <a href=\"https:\/\/beeindia.gov.in\/WriteReadData\/L45218\/1734687573.pdf\" target=\"_blank\" rel=\"noopener\">BEE room-air-conditioner label rules<\/a> list cooling capacity and power consumption as separate label particulars. BEE\u2019s <a href=\"https:\/\/udit.beeindia.gov.in\/standards-labeling\/\" target=\"_blank\" rel=\"noopener\">Standards and Labelling programme<\/a> also explains how appliance labels help consumers compare energy performance.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Step 1: Read the AC label correctly<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Why this matters:<\/strong> \u201c1.5 ton\u201d describes the cooling capacity. It does not mean that the AC always draws exactly 1,500 W from the inverter.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Find the model label, manual or technical data sheet. Write down the input power in watts. If the specification gives a range, use the higher rated input for the first inverter check. Also note whether the AC has a variable-speed compressor.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For example, suppose your label says <strong>1,500 W power consumption<\/strong>. That is the number used in the rest of this worked example. It is an assumption for learning the calculation, not a claim about every 1.5-ton AC.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">If your AC label lists only cooling capacity or you cannot identify the input-power figure, pause here and find the exact model specification. Guessing from tonnage can lead to an inverter that is too small.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Step 2: Add the running load<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Why this matters:<\/strong> The AC will not be the only thing connected to the inverter. Your inverter must supply the combined load when all selected appliances are on.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Write the running watts for each appliance and add them:<\/p>\n\n\n\n<figure class=\"wp-block-table ap-table\"><table><thead><tr><th>Appliance<\/th><th>Running load in this example<\/th><\/tr><\/thead><tbody><tr><td>1.5-ton AC<\/td><td>1,500 W<\/td><\/tr><tr><td>Fans, lights and Wi-Fi router<\/td><td>300 W<\/td><\/tr><tr><td><strong>Total continuous load<\/strong><\/td><td><strong>1,800 W<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Use your own numbers. A fan or light that you plan to leave off during a power cut should not be included. A refrigerator, pump or other motor that may start automatically should be included even if it does not run continuously.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">You can use the <a href=\"https:\/\/vatowatt.com\/power-consumption-calculator\">Power Consumption Calculator<\/a> to estimate the wattage and daily energy of the appliances in your home. For inverter sizing, the important starting point is the set of appliances that may run at the same time.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/vatowatt.com\/blog\/wp-content\/uploads\/2026\/10\/inverter-for-1-5-ton-ac-1.webp\" alt=\"Enter the AC wattage, startup multiplier, runtime and battery preferences in the Inverter Load Calculator.\"\/><figcaption class=\"wp-element-caption\">Enter the AC wattage, startup multiplier, runtime and battery preferences in the Inverter Load Calculator.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Step 3: Allow for compressor startup surge<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Why this matters:<\/strong> An AC compressor can need a short burst of power when it starts. An inverter can have enough continuous watts but still trip if its peak rating is too low.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Use this screening calculation:<\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>AC startup load = AC running watts \u00d7 startup multiplier<\/code><\/pre>\n\n\n\n<p class=\"wp-block-paragraph\">If you use the calculator\u2019s <strong>3x<\/strong> planning option for the 1,500 W example:<\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>AC startup load = 1,500 W \u00d7 3 = 4,500 W\nCombined peak screening load = 4,500 W + 300 W = 4,800 W<\/code><\/pre>\n\n\n\n<p class=\"wp-block-paragraph\">The 3x value is a planning input, not a measurement of your AC. An inverter AC, a fixed-speed AC and different models can have different starting behaviour. Check the AC and inverter manuals for their actual starting or peak requirements where available.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">When comparing an inverter, check both values:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n\n<li><strong>Continuous rating:<\/strong> must cover the combined running load.<\/li>\n\n\n<li><strong>Peak or surge rating:<\/strong> must cover the compressor-start estimate and other devices that may start together.<\/li>\n\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Do not judge the inverter by its VA label alone. Look for the continuous watt rating, peak watt or VA rating, output waveform requirement and stated compatibility with motor or compressor loads.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Step 4: Convert watts to VA<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Why this matters:<\/strong> Inverter capacity is commonly advertised in VA, while appliance labels show watts. Power factor connects the two.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Use:<\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>VA = watts \u00f7 power factor<\/code><\/pre>\n\n\n\n<p class=\"wp-block-paragraph\">With VatoWatt\u2019s Indian planning default of <strong>PF 0.8<\/strong>, the 1.5-ton AC example becomes:<\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>AC only:       1,500 W \u00f7 0.8 = 1,875 VA\nAC plus 300 W: 1,800 W \u00f7 0.8 = 2,250 VA<\/code><\/pre>\n\n\n\n<p class=\"wp-block-paragraph\">So this example needs at least <strong>2,250 VA of continuous capacity before any extra margin<\/strong>. The next available inverter size must be above that calculated requirement, and its peak specification must also pass the startup check from Step 3.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">If your AC label says 1,200 W, the same calculation is 1,500 VA for the AC alone. If it says 1,800 W, it is 2,250 VA before other loads. This is why a model-specific label beats a generic \u201c1.5-ton AC wattage\u201d chart.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Step 5: Size the battery bank for backup hours<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Why this matters:<\/strong> A large inverter can run a load, but it cannot create battery energy. AC backup becomes battery-heavy as the required hours increase.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For a simple estimate using the inverter calculator\u2019s defaults, use:<\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>Battery Ah = load watts \u00d7 backup hours\n             \u00f7 (battery volts \u00d7 inverter efficiency \u00d7 usable discharge fraction)<\/code><\/pre>\n\n\n\n<p class=\"wp-block-paragraph\">The defaults are <strong>85% inverter efficiency<\/strong> and <strong>50% maximum depth of discharge<\/strong>. For the 1,500 W AC alone on a 24 V system for 4 hours:<\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>Battery Ah = 1,500 \u00d7 4 \u00f7 (24 \u00d7 0.85 \u00d7 0.50)\n           = 6,000 \u00f7 10.2\n           = 588.24 Ah at 24 V<\/code><\/pre>\n\n\n\n<p class=\"wp-block-paragraph\">That is a large bank. With the same 4-hour target on 48 V:<\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>Battery Ah = 1,500 \u00d7 4 \u00f7 (48 \u00d7 0.85 \u00d7 0.50)\n           = 294.12 Ah at 48 V<\/code><\/pre>\n\n\n\n<p class=\"wp-block-paragraph\">The watt-hours are similar, but the Ah number changes with system voltage. Do not compare a 24 V battery bank and a 48 V battery bank by Ah alone.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Here is a runtime example using a 24 V, 200 Ah bank:<\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>Usable AC energy = 24 \u00d7 200 \u00d7 0.50 \u00d7 0.85\n                 = 2,040 Wh\n\nRuntime for 1,500 W AC = 2,040 \u00f7 1,500\n                        = 1.36 hours, or about 1 hour 22 minutes<\/code><\/pre>\n\n\n\n<p class=\"wp-block-paragraph\">With the extra 300 W load, the same estimate is <code>2,040 \u00f7 1,800 = 1.13 hours<\/code>, or about 1 hour 8 minutes. Actual runtime varies with battery type, age, temperature, discharge rate and changing AC load. Treat the result as a sizing estimate, not a guaranteed runtime.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For a second calculation, the <a href=\"https:\/\/vatowatt.com\/battery-backup-calculator\">Battery Backup Calculator<\/a> uses battery Ah, voltage, load watts and an efficiency factor to estimate runtime. Enter the battery bank\u2019s actual voltage and capacity, not the rating of only one battery in a series bank.<\/p>\n\n\n\n<aside class=\"ap-note\"><p>Battery banks can deliver very high fault current. Do not wire, series-connect or service batteries while energised; isolate the system and use a licensed electrician for a permanent installation.<\/p><\/aside>\n\n\n\n<h2 class=\"wp-block-heading\">Step 6: Check the numbers in the calculator<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Why this matters:<\/strong> A calculator makes it easier to include every appliance and change the backup time without losing track of units.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Open the <a href=\"https:\/\/vatowatt.com\/inverter-load-calculator\">Inverter Load Calculator<\/a> and enter:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n\n<li>The AC\u2019s labelled input watts, quantity 1 and the number of hours you expect it to run.<\/li>\n\n\n<li>The startup multiplier as a planning value, then change it if the AC manufacturer gives a better figure.<\/li>\n\n\n<li>Every fan, light, router, refrigerator or other appliance that may run at the same time.<\/li>\n\n\n<li>Your desired backup time. If you want 4 hours, replace the default with 4; do not leave 8 hours unless that is your real target.<\/li>\n\n\n<li>Inverter efficiency of 85%, the battery voltage, and maximum depth of discharge of 50% for the worked example.<\/li>\n\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">The result should show continuous power, startup power, inverter VA and battery Ah. Compare those results with the exact inverter\u2019s data sheet. If the calculator result and the manufacturer\u2019s rating use different units, convert them before comparing.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Verify the recommendation before buying<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Use this final checklist:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n\n<li>The AC input watts came from the exact model label or manual.<\/li>\n\n\n<li>The inverter\u2019s continuous watt and VA ratings exceed the combined running load.<\/li>\n\n\n<li>The inverter\u2019s peak rating covers the compressor-start estimate.<\/li>\n\n\n<li>The output voltage and waveform meet the AC and inverter manufacturer requirements.<\/li>\n\n\n<li>The battery bank voltage matches the inverter, and its Ah capacity meets the desired hours.<\/li>\n\n\n<li>The system is suitable for India\u2019s 230 V, 50 Hz supply and is installed by a licensed electrician.<\/li>\n\n\n<li>You have not counted the AC\u2019s cooling-capacity watts as its electrical input watts.<\/li>\n\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Common mistakes and troubleshooting<\/h2>\n\n\n\n<figure class=\"wp-block-table ap-table\"><table><thead><tr><th>Problem<\/th><th>Likely reason<\/th><th>What to check<\/th><\/tr><\/thead><tbody><tr><td>The inverter trips as the AC starts<\/td><td>Peak rating is too low or another motor starts with it<\/td><td>Check the AC\u2019s starting requirement and inverter peak rating<\/td><\/tr><tr><td>The inverter runs but backup ends quickly<\/td><td>Load, hours or battery capacity was underestimated<\/td><td>Re-enter all simultaneous loads and recalculate Ah<\/td><\/tr><tr><td>A 24 V system appears to have the same Ah as a 12 V system<\/td><td>Ah was compared without voltage<\/td><td>Compare watt-hours: volts \u00d7 Ah<\/td><\/tr><tr><td>The calculated inverter looks too small<\/td><td>Cooling capacity was used instead of power consumption<\/td><td>Re-read the AC label and use input watts<\/td><\/tr><tr><td>Runtime changes during the day<\/td><td>Variable-speed AC input and room conditions change<\/td><td>Size from rated input, then treat runtime as an estimate<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Never open the inverter or alter live mains connections to solve a trip or startup problem. Use the product manuals and a licensed electrician for diagnosis and installation.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">When is running an AC on an inverter practical?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">It can be practical for a short outage when you have a correctly sized inverter and enough battery energy. The maths becomes less attractive when you want several hours of cooling: the 1,500 W example needs about 588 Ah at 24 V for 4 hours under the stated assumptions, before adding fans, lights or a refrigerator.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">If your priority is a longer backup, compare two scenarios in the calculator: AC only and essential loads only. This shows the battery trade-off clearly and lets you choose a realistic backup time without assuming that one 12 V battery will run everything.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">FAQ<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Can a 1.5-ton AC run on an inverter?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Yes, if the inverter\u2019s continuous output, peak rating, output requirements and battery bank all match the AC\u2019s specification. The AC\u2019s 1.5-ton label alone does not prove that a particular inverter will start it.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">What size inverter is needed for a 1.5-ton AC?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Read the AC\u2019s input watts first. If the label says 1,500 W, the AC alone is 1,875 VA at PF 0.8; with another 300 W of appliances, the continuous calculation becomes 2,250 VA. Check the inverter\u2019s peak rating separately for compressor startup.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">How many batteries are needed for a 1.5-ton AC?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">There is no fixed battery count because the answer depends on voltage, Ah capacity, AC watts and backup hours. For example, a 24 V, 200 Ah bank gives an estimated 1.36 hours for a 1,500 W AC under 85% efficiency and 50% discharge assumptions.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">How long will a battery run a 1.5-ton AC?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Use <code>hours = battery Ah \u00d7 battery V \u00d7 efficiency \u00f7 load W<\/code> for a quick runtime estimate, then apply the usable discharge limit you plan to follow. Enter the exact battery and AC numbers in the Battery Backup Calculator because an inverter AC\u2019s load can change while it runs.<\/p>\n\n\n\n<aside class=\"ap-cta\" aria-label=\"Size your inverter and battery\"><div class=\"ap-cta__content\"><p class=\"ap-cta__eyebrow\">Recheck your load<\/p><p class=\"ap-cta__title\">Size your inverter and battery<\/p><p class=\"ap-cta__text\">Enter your AC, startup multiplier and backup hours to get a watt, VA and Ah estimate.<\/p><\/div><a class=\"ap-cta__btn\" href=\"https:\/\/vatowatt.com\/inverter-load-calculator\">Open the calculator<\/a><\/aside>\n\n\n\n<h2 class=\"wp-block-heading\">Related calculators<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n\n<li><a href=\"https:\/\/vatowatt.com\/\">VA to Watt Converter<\/a><\/li>\n\n\n<li><a href=\"https:\/\/vatowatt.com\/watt-to-va\">Watt to VA Converter<\/a><\/li>\n\n\n<li><a href=\"https:\/\/vatowatt.com\/inverter-load-calculator\">Inverter Load Calculator<\/a><\/li>\n\n\n<li><a href=\"https:\/\/vatowatt.com\/battery-backup-calculator\">Battery Backup Calculator<\/a><\/li>\n\n\n<li><a href=\"https:\/\/vatowatt.com\/solar-panel-calculator\">Solar Panel Calculator<\/a><\/li>\n\n\n<li><a href=\"https:\/\/vatowatt.com\/power-consumption-calculator\">Power Consumption Calculator<\/a><\/li>\n\n<\/ul>\n\n\n\n<script type=\"application\/ld+json\">{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"Can a 1.5-ton AC run on an inverter?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes, if the inverter\u2019s continuous output, peak rating, output requirements and battery bank all match the AC\u2019s specification. The AC\u2019s 1.5-ton label alone does not prove that a particular inverter will start it.\"}}, {\"@type\": \"Question\", \"name\": \"What size inverter is needed for a 1.5-ton AC?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Read the AC\u2019s input watts first. If the label says 1,500 W, the AC alone is 1,875 VA at PF 0.8; with another 300 W of appliances, the continuous calculation becomes 2,250 VA. Check the inverter\u2019s peak rating separately for compressor startup.\"}}, {\"@type\": \"Question\", \"name\": \"How many batteries are needed for a 1.5-ton AC?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"There is no fixed battery count because the answer depends on voltage, Ah capacity, AC watts and backup hours. For example, a 24 V, 200 Ah bank gives an estimated 1.36 hours for a 1,500 W AC under 85% efficiency and 50% discharge assumptions.\"}}, {\"@type\": \"Question\", \"name\": \"How long will a battery run a 1.5-ton AC?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Use hours = battery Ah \u00d7 battery V \u00d7 efficiency \u00f7 load W for a quick runtime estimate, then apply the usable discharge limit you plan to follow. Enter the exact battery and AC numbers in the Battery Backup Calculator because an inverter AC\u2019s load can change while it runs.\"}}]}<\/script>\n\n","protected":false},"excerpt":{"rendered":"Need an inverter for ac? Learn how to read the AC label, calculate watts to VA, allow for startup surge and size a 24 V or 48 V battery bank.","protected":false},"author":2,"featured_media":39,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"csco_singular_sidebar":"","csco_page_header_type":"","csco_page_load_nextpost":"","footnotes":""},"categories":[10],"tags":[24,25,5,12,23],"class_list":["post-38","post","type-post","status-publish","format-standard","has-post-thumbnail","category-inverters-ups","tag-1-5-ton-ac","tag-ac-power","tag-battery-backup","tag-inverter-sizing","tag-inverter-for-ac","cs-entry"],"_links":{"self":[{"href":"https:\/\/vatowatt.com\/blog\/wp-json\/wp\/v2\/posts\/38","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/vatowatt.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/vatowatt.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/vatowatt.com\/blog\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/vatowatt.com\/blog\/wp-json\/wp\/v2\/comments?post=38"}],"version-history":[{"count":1,"href":"https:\/\/vatowatt.com\/blog\/wp-json\/wp\/v2\/posts\/38\/revisions"}],"predecessor-version":[{"id":231,"href":"https:\/\/vatowatt.com\/blog\/wp-json\/wp\/v2\/posts\/38\/revisions\/231"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/vatowatt.com\/blog\/wp-json\/wp\/v2\/media\/39"}],"wp:attachment":[{"href":"https:\/\/vatowatt.com\/blog\/wp-json\/wp\/v2\/media?parent=38"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/vatowatt.com\/blog\/wp-json\/wp\/v2\/categories?post=38"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/vatowatt.com\/blog\/wp-json\/wp\/v2\/tags?post=38"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}